- Take LuciPac Pen tubes out of the refrigerator 20 min prior to use and bring them to room temperature. Do not use cold LuciPac Pen test tubes.
- Turn on Lumitester PD-20 by pressing POWER button.
- Remove swab stick (orange holder) from the test tube.
- Moisten swab with tap water.
- Swab the surface which you want to test.
- Put the swab back into the tube and push it downwards until the holder is completely inserted into the tube.
- Shake the LuciPac Pen repeatedly in direction of arrow (horizontal) so that the liquid in the capsule falls into the reaction tube and dissolves the regent.
- Insert the LuciPac Pen into the measuring chamber of the Lumitester PD-20 and close the chamber cover.
- Press ENTER to start the measurement. The result will be displayed after a countdown from 10 to 0. Keep instrument steady in an upright position during the measurement.
- Remove LuciPac Pen from the chamber after measurement.
AMP/ATP measurement with LuciPac Pen and Lumitester PD-20
- Prior to performance of the first test with LuciPac Pen and Lumitester PD-20 read the instructions for preparation of the device and follow the steps for installation which are described within the instruction manual.
- The manual can be found on the CD which is included in the package. The manual also contains a detailed description of the handling of the device.
- Please note that the control software has to be installed first before connecting the Lumitester PD-20 to a computer.
- The driver software will be installed after the connection has been made.
- Instructions for installation are included in the instruction manual for the control software.
Back to top
MICROBIOLOGICAL TEST SHEETS
RIDA Count – the test sheet that counts for you.
Our patented solution for hygiene monitoring and food control.
To meet the increasing demands in routine microbiological analysis, Bodinco offers an interesting answer – the RIDA COUNT test sheets. These sheets have the following benefits: easy handling, long shelf life, and minimum space requirement for storage and incubation.
A unique patented fibre layer provides for all types of applications in food microbiology.
Fast and safe contact tests / swab tests for checking surfaces, automated air samples and the direct incubation of membrane filters, facilitate routine analysis. RIDA COUNT absorbs liquids applied such as water and beverages as well as all common diluting media for food samples.
A covering film prevents any leakage of sample solution.
RIDA COUNT provides a combination of hygiene monitoring and microbiological product checks in a simple, safe and economic way.
- RIDA COUNT Total (Art. No. R1001)
For the detection of mesophilic aerobic total count
(AOAC-RI approved, Certificate-No.:011001)
- RIDA COUNT Coliform (Art. No. R1002)
For the detection of coliforms
(AOAC-RI approved, Certificate-No.:100402)
- RIDA COUNT Staph. aureus (Art. No. R1005)
For the detection of Staphylococcus aureus
- RIDA COUNT E. coli (Art .No. R1006)
For the detection of Escherichia coli
- RIDA COUNT E. coli / Coliform (Art. No. R1007)
For the detection of Escherichia coli and coliforms
- RIDA COUNT Yeast & Mold Rapid (Art. No. R1008)
For the detection of yeasts & molds in 48 h
- RIDA COUNT Enterobacteriaceae (Art. No. R1009)
For the detection of Enterobacteriaceae
- RIDA COUNT Salmonella / Enterobacteriaceae (Art. No. R1010)
For the detection of Salmonella spp. and Enterobacteriaceae
Back to top
PROTEIN DETECTION SWABS RIDA CHECK
Art. No. R1091 – 100 tests
Art. No. R1092 – 40 tests
Ready-to-use swab system for the detection of protein residues in cleansing control and as preliminary screening for potential allergens on surfaces
Test information:
- Easy handling
- open package
- take swab sample
- read result
- Swab changes colour if proteins are present
- No preparation of reagents
- No instruments for measuring or laboratory equipment needed
- Results within a few seconds
- Sensitive detection of protein residues (LOD 20 ug)
- Cost-efficient alternative to ATP-measurements
|